AUTO
CONTROL FOR pH AND ALUM
IN Paper mills pH of head box is
maintained by addition of alum & rosin manually in mixing
chest which makes lot of corrision in all pipings ,pump and
agitators . this whole operation is controlled by human beings
& their is always chances of variation in dose of alum ,
which finally results in pH variation at head box of machine .
It is a world wide paper maker`s
experience that variation in pH at paper M/c`s head box plays a
greater roll in runability of paper machine and as well as
quality of paper products in view of paper sizing .
To over come these problems , we have
auto control for paper m/c head box`s pH , alum & rosing
dosing which has following advantages besides of manually
handling and control of alum & rosin dosing .
(1)Up to 20% saving in alum consumption
(2)0.5% to 1.0% saving in rosin
consumption .
(3)Minimize cobb variation
(4)Improves paper machine runability .
(5)Eliminates corrosion problem in
approach flow pipe lines , pumps , agitators and other allied
eqipments .
(6)Fast pay back period i.e less than
three month .
P
& I DIAGRAM OF pH CONTROL

CONSISTENCY
CONTROL SYSTEMS
THE SYSTEM USES A
CONSISTENCY TRANSMITTER WHICH MEASURES THE CONSISTENCY OF PULP
AND SIGNAL ARE TRANSFERED TO THE PID CONTROLLER.
PID CONTROLLER MATCHES
THE CONSISTENCY VALUE WITH THE SET VALUE AND THEN THE CONTROL
ACTION IS DONE BY OPENING OF THE DILUTION VALVE IN SUCTION OF THE
PUMP AS PER THE CONSISTENCY MEASURED.
SYSTEM RUNS
AUTOMATICALLY AT THE SET VALUE OF THE CONSISTENCY.
P
& I DIAGRAM OF CONSISTENCY CONTROL

STEAM
PRESSURE CONTRL SYSTEMS
THE SYSTEM USES A
PRESSURE TRANSMITTER WHICH MEASURES THE PRESSURE OF STEAM LINE
AND SIGNAL ARE TRANSFERED TO THE PID CONTROLLER.
PID CONTROLLER MATCHES
THE PRESSURE VALUE WITH THE SET VALUE AND THEN THE CONTROL ACTION
IS DONE BY OPENING OF THE STEAM CONTROL VALVE.
SYSTEM RUNS
AUTOMATICALLY AT THE SET VALUE OF THE PRESSURE.
BENIFITS :-
1. SYSTEM SAVES THE STEAM
2. CONTROL IS VERY FAST
3. REJECTION OF PAPER IS
MINIMISED.
DRUM
LEVEL CONTROL SYSTEM


THE SYSTEM USES A LEVEL
TRANSMITTER WHICH MEASURES THE LEVEL OF DRUM OF BOILER &
SIGNALS ARE TRANSFERED TO THE PID CONTROLLER.
PID CONTROLLER MATCHES
THE LEVEL VALUE WITH THE SET VALUE AND THEN THE CONTROL ACTION IS
DONE BY OPENING OF THE VALVE IN DELIVERY OF THE PUMP AS PER THE
LEVEL MEASURED.
SYSTEM RUNS
AUTOMATICALLY AT THE SET VALUE OF THE LEVEL OF THE DRUM.